Iai-america RCP2-RTCBL Instrukcja Użytkownika Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 80
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
7. Notes on use of cable bearers
z Do not let the cable get tangled or kinked in a cable bearer or flexible tube. When bundling the cable,
keep a certain degree of flexibility (so that the cable will not become too taut when bent).
z Do not cause the cables to occupy more than
60% of the space in the cable bearer.
z Do not lay signal lines together with circuit lines
that create a strong electric field.
z The supplied cable is not a robot
cable. Accordingly, never store the
supplied cable in a cable bearer.
z Use a cable bearer with its bending
radius r set to 50 mm or greater.
z If a relay cable is to
be used, always
use a robot cable.
Bending radius r
Cable
Cable bearer
Power line
Signal lines
(flat cable)
Duct
Przeglądanie stron 5
1 2 3 4 5 6 7 8 9 10 11 ... 79 80

Komentarze do niniejszej Instrukcji

Brak uwag